Public law 101 608 section 203 f.
Residential garage door safety requirements.
Block the photo eye with an object over 6 inches tall and press the garage door opener s close button.
This means that sensors rpm.
How does a residential garage door meet the ul325 standards.
So for all these reasons the international residential code irc and residential edition of the florida building code fbc r302 5 have safety standards for a door that separates the garage from the house interior.
Torsion springs mount on a bar above the door while extension springs stretch down the side of the upper tracks.
Inherent entrapment protection must exist as a primary form of entrapment protection.
On june 19 1991 the commission issued the garage door operator standard 16 cfr part 1211.
Garage doors use either torsion springs or extension springs to raise and lower the door.
Any other exterior door has a threshold height limited to 7 inches.
Solid wood door not less than 1 3 8 thick.
This is a mandatory requirement for operation other than constant contact to close.
Knowing garage door clearance requirements will help you avoid ordering the wrong garage door set up for your needs.
A door with a 20 minute fire rating.
Inability to comply will result in the operator being limited to constant contact to close operation.
The improvement act contains a preemption provision which states.
1 i for a horizontally sliding residential garage door operator system other than for the first 1 foot 305mm of door travel from the full closed position both with and without any external entrapment protection device functional the operator of a closing residential garage door shall initiate reversal of the door within 2 seconds of contact with the obstruction as specified in paragraph c 3 of this section.
All commercial door operators bearing the ul label must continuously monitor safety devices such as photo sensors and or sensing edges.
The door should not close.
Means of egress doors in the irc 2018 irc section r311 3 1 restricts threshold height a required exit door in residences to 1 inches from the top of the the threshold to the floor or landing on each side of the door.
The consumer product safety improvement act of 1990 improvement act mandated that automatic residential garage door operators gdos manufactured on or after january 1 1991 conform to the entrapment protection requirements of the 1988 version of ul 325.
The door cannot open directly onto a room used for sleeping purposes bedroom and must be one of the following types.